Assessment of haemoglobin measurement by several methods - blood gas analyser, capillary and venous HemoCue® , non-invasive spectrophotometry and lab…
2018
A laboratory haematology analyser is the gold standard for measuring haemoglobin concentration but has disadvantages, especially in neonates. This study compared alternative blood-sparing and non-invasive methods of haemoglobin concentration measurement with the gold standard. Haemoglobin concentrations were measured using a laboratory haematology analyser (reference method), blood gas analyser, HemoCue® using venous and capillary blood samples and a newly developed non-invasive sensor for neonates < 3 kg. A total of 63 measurements were performed. Body weight (2190 (1820-2520 [967-4450]) g) and haemoglobin concentration (12.3 (10.6-15.2 [8.2-20.5]) g.dl-1 ) varied widely. Bias/limits of ag…
Inter-laboratory evaluation of the ISO standard 11063 "Soil quality - Method to directly extract DNA from soil samples"
2011
International audience; Extracting DNA directly from micro-organisms living in soil is a crucial step for the molecular analysis of soil microbial communities. However, the use of a plethora of different soil DNA extraction protocols, each with its own bias, makes accurate data comparison difficult. To overcome this problem, a method for soil DNA extraction was proposed to the International Organization for Standardization (ISO) in 2006. This method was evaluated by 13 independent European laboratories actively participating in national and international ring tests. The reproducibility of the standardized method for molecular analyses was evaluated by comparing the amount of DNA extracted, …
Inter-laboratory evaluation of the ISO standard 11063 "Soil quality -- Method to directly extract DNA from soil samples"
2011
International audience; Extracting DNA directly from micro-organisms living in soil is a crucial step for the molecular analysis of soil microbial communities. However, the use of a plethora of different soil DNA extraction protocols, each with its own bias, makes accurate data comparison difficult. To overcome this problem, a method for soil DNA extraction was proposed to the International Organization for Standardization (ISO) in 2006. This method was evaluated by 13 independent European laboratories actively participating in national and international ring tests. The reproducibility of the standardized method for molecular analyses was evaluated by comparing the amount of DNA extracted, …